Introduction

Light manufacturing facilities require flooring systems that can endure moderate mechanical stresses, foot traffic, and occasional equipment movement while maintaining a clean, organized, and professional appearance. The flooring must also resist light chemical exposure and be easy to maintain.

The Epoxy Flooring System for – Light Manufacturing Plants is a medium-duty, high-build flooring solution engineered to provide an optimal balance between durability, functionality, and aesthetics for precision manufacturing and assembly environments.

Recommended Use Cases

  • Electrical and electronic component assembly areas
  • Plastic, rubber, and polymer product manufacturing units
  • Medical device and packaging facilities
  • Consumer goods assembly and testing areas
  • Printing and finishing workshops
  • Light metal fabrication and tool maintenance zones

Step-Wise System Description

Step 1: Surface Preparation

  • A clean, sound, and properly profiled surface is vital for long-term epoxy performance.
  • All necessary surface repairs, including crack filling or substrate restoration, must be completed before application.
  • Mechanically grind or shot-blast the concrete surface to remove weak or contaminated layers.
  • Repair cracks and imperfections using epoxy crack fillers.
  • Clean thoroughly and vacuum all debris.
  • Ensure substrate moisture content is below 5% before primer application.

Step 2: Application of Ressi EPO Primer LV

  • Apply Ressi EPO Primer LV, a low-viscosity, solvent-free epoxy primer for strong bonding and surface sealing.
  • Mix resin and hardener as per technical datasheet.
  • Apply evenly using roller or brush.
  • Allow full curing before subsequent layers.

Step 3: Application of Ressi EPO Mid Coat S – GP (Optional)

  • Apply when additional levelling or build thickness is required.
  • Recommended thickness: 1000–2000 microns.
  • Apply using trowel/squeegee and finish with spike roller.
  • Allow overnight curing.
  • This step is optional if substrate is already level.

Step 4: Application of Final Epoxy Topcoat

  • Apply Ressi EPO Tough Might as final wear layer.
  • If mid coat is used: apply at 1000 microns.
  • If no mid coat: apply Ressi EPO Floor Plus at minimum 2000 microns.
  • Apply using roller or flat squeegee for smooth finish.
  • Allow 48–72 hours for light traffic and 7 days for full cure.

Step 5: Floor Markings (If Required)

  • Use Ressi EPO Gloss Might for workflow zoning and markings.
  • Apply after full curing of base system.
  • Use masking tape for clean edges.
  • Allow proper curing before traffic.

Note:

  • Total system thickness must be minimum 2000 microns.
  • Refer to Technical Datasheets (TDS) for mixing and application details.

System Advantages

  • Durable and Functional: Handles mechanical wear and foot traffic.
  • Customizable Thickness: Adaptable to operational loads.
  • Chemical Resistance: Suitable for mild chemical exposure.
  • Smooth and Seamless Finish: Clean, professional appearance.
  • Easy Maintenance: Non-porous, dust-free surface.
  • Optional Floor Markings: Supports workflow and safety zoning.

Maintenance Guidelines

  • Clean using neutral pH cleaning agents.
  • Avoid harsh solvents or abrasive tools.
  • Inspect periodically and recoat when required.
  • Repair surface damage promptly.

System Summary Table

ParameterDescription
System NameEpoxy Flooring System for – Light Manufacturing Plants
Area TypeLight Manufacturing, Assembly, and Fabrication Zones
Traffic ExposureMedium Duty
Primary RequirementsDurability, Smooth Finish, Easy Maintenance, Mild Chemical Resistance
PrimerRessi EPO Primer LV
Mid Coat (Optional)Ressi EPO Mid Coat S – GP (1000–2000 microns)
TopcoatRessi EPO Tough Might (with Mid Coat) / Ressi EPO Floor Plus (without Mid Coat)
Marking Coat (Optional)Ressi EPO Gloss Might (Roller Applied, Alternate Color)
Total System ThicknessMinimum 2000 Microns
Finish TypeSmooth, Gloss
Curing Time Before Use48–72 Hours for Mild Traffic / 7 Days Full Cure
Key BenefitsDurable, Seamless, Easy to Clean, Professional Finish

Conclusion

The Epoxy Flooring System for – Light Manufacturing Plants provides a robust, cost-effective, and easy-to-maintain flooring solution ideal for precision and assembly-oriented industries. The process — Surface Preparation, Ressi EPO Primer LV, (Optional) Ressi EPO Mid Coat S – GP, Ressi EPO Tough Might or Ressi EPO Floor Plus, (Optional) Ressi EPO Gloss Might — ensures a smooth, long-lasting surface that meets both functional and aesthetic requirements of light manufacturing environments.

System Summary

System Summary

A Cementitious Surface: (Concrete slab or screed)
B Cracks and surface damage
C Crack Filler and Repairing Materials
D Ressi EPO Primer LV
E Ressi EPO Mid Coat S – GP
F Ressi EPO Tough Might / Ressi EPO Floor Plus
G Ressi EPO Gloss Might

View PDFView Application PDF