Ressichem logo
Ressichem logo

EPOXY FLOORING SYSTEM FOR – ESD-CONTROLLED CLEANROOM ENVIRONMENTS

Introduction

Cleanroom environments demand extremely precise electrostatic discharge (ESD) control to protect sensitive equipment, maintain contamination-free conditions, and ensure uninterrupted performance of precision operations. Even a minor electrostatic imbalance can result in component failure, data corruption, or product rejection.

The Epoxy Flooring System for ESD-Controlled Cleanroom Environments by Ressichem provides a highly conductive, seamless, and durable epoxy floor system specifically engineered for cleanroom-grade environments. It ensures controlled and uniform static dissipation, in coordination with grounding networks, while maintaining a smooth, hygienic, and low-particle-emitting surface.

Recommended Use Cases

  • Semiconductor and microchip manufacturing
  • Pharmaceutical cleanrooms
  • Medical device production facilities
  • Precision laboratories and calibration zones
  • Aerospace and defense electronics assembly
  • Research & development centers with controlled ESD

Step-Wise System Description

Step 1: Surface Preparation

Proper substrate evaluation and preparation are critical to ensure uniform grounding and long-term ESD performance.

  • All necessary surface repairs, including crack filling or substrate restoration, must be completed prior to the application of any epoxy flooring materials.
  • The concrete strength requirement must be defined by the project consultant as per the operational load profile.
  • Perform both destructive (core sample) and non-destructive Schmidt Hammer strength testing to verify substrate integrity.
  • For major repairs ≥ 12 mm, apply Ressi NSG 710, a high-strength, non-shrink cementitious repair mortar.
  • For minor imperfections, use Ressi EPO Primer LV blended with Ressichem’s washed, graded, and completely dried silica sand to form a moisture-free repair paste.
  • Mechanically prepare the substrate through shot blasting or diamond grinding to ensure an oil-free, dust-free surface.
  • In previously used floors, ensure full removal of oil or grease contamination before application.

Step 2: Application of Ressi SLS Primer – 1 and Ressi SLS 610 (If Required)

  • If leveling is required to achieve a uniform substrate before epoxy application, apply Ressi SLS Primer – 1 followed by Ressi SLS 610, a self-leveling cementitious floor screed.
  • Allow 7–14 days for the screed to release moisture depending on ambient temperature and humidity before proceeding with epoxy installation.
  • Ensure moisture level < 5% before further coating.

Step 3: Application of Ressi EPO Primer LV and Copper Strip Installation

  • Apply Ressi EPO Primer LV, a low-viscosity, solvent-free epoxy primer that promotes bonding and surface sealing.
  • During this stage, the copper grounding network is integrated into the flooring system.
  • Copper strips are bonded using Ressi EPO Primer LV over the prepared surface.
  • The spacing, width, and thickness of the copper strips are to be determined according to the client’s ESD requirement.
  • Once installed, the continuity and discharge capacity of the grounding system should be tested and verified before applying the conductive topcoat.
  • This ensures that the entire copper grid forms a consistent and functional discharge path across the floor area.

Step 4: Application of Ressi EPO Anti-Static

  • Apply Ressi EPO Anti-Static, a conductive epoxy topcoat that ensures seamless conductivity across the surface and effective connection to the copper grounding system.
  • Apply the material at a minimum thickness of 1000 microns above the height of the copper strip layout.
  • For example: if the copper strip thickness is 1000 microns, the total topcoat thickness should be 2000 microns.
  • Apply using a notched trowel or epoxy squeegee, followed by back rolling to achieve a uniform finish.
  • Allow the coating to fully cure before conducting ESD validation.

Step 5: Floor Markings (If Required)

  • For cleanroom demarcations, apply Ressi EPO Anti-Static in a contrasting color using a roller at a thin coat thickness.
  • This ensures that the visual layout complements the conductive flooring while maintaining its electrical continuity.

System Advantages

  • Seamless ESD Control: Maintains consistent conductivity across the entire cleanroom floor area.
  • High Cleanroom Compatibility: Smooth, dust-free, and low-particulate surface.
  • Chemical Resistance: Withstands common cleaning and sterilization agents.
  • Durability: Designed for heavy-duty cleanroom equipment and wheeled traffic.
  • Hygienic Surface: Non-porous and easy to clean, maintaining GMP compliance.
  • Grounded Safety: Provides reliable discharge pathways via copper strip integration.
  • Customizable Finish: Available in cleanroom-appropriate colors and gloss levels.

Maintenance Guidelines

  • Use only neutral pH cleaners to maintain coating integrity and conductivity.
  • Avoid applying insulating waxes or sealers over the ESD surface.
  • Inspect grounding points periodically for continuity.
  • Periodic re-coating may be required to restore finish and maintain ESD consistency.
  • Keep the cleanroom climate controlled to ensure consistent ESD performance.

System Summary Table

ParameterDescription
System NameEpoxy Flooring System for – ESD-Controlled Cleanroom Environments
Area TypeSpecialized / High-Performance – Cleanroom & ESD-Controlled Facilities
Traffic ExposureLight to Heavy (as per cleanroom equipment)
Primary RequirementsControlled ESD Discharge and Grounding Integration
Primer (Optional)Ressi SLS Primer – 1 (for SLS systems)
Leveling Layer (Compulsory)Ressi SLS 610 (if required)
Epoxy PrimerRessi EPO Primer LV (used for both priming and copper bonding)
Conductive LayerRessi EPO Anti-Static (≥ 1000 microns above copper layout)
Silica UsedWashed, graded, and completely dried (zero moisture content) silica sand
Copper Grid NetworkInstalled and grounded as per site-specific ESD requirements
Application MethodHigh-Build Trowel or Epoxy Squeegee
Finish TypeSmooth, Low-Gloss / Semi-Gloss Conductive Finish
Curing Time Before Use48–72 Hours (Light Access) / 7 Days (Full Cure)
Key BenefitsESD Control, Durability, GMP Hygiene, Grounding Integration

Conclusion

The Epoxy Flooring System for ESD-Controlled Cleanroom Environments by Ressichem is a precision-engineered conductive epoxy system that integrates copper grounding with anti-static technology for complete electrostatic discharge management.

The combination of Ressi EPO Primer LV, embedded copper grid, and Ressi EPO Anti-Static creates a robust, hygienic, and reliable flooring solution tailored for pharmaceutical, semiconductor, and medical cleanroom environments.

System Summary

System Summary

A Cementitious Surface: (Concrete slab or screed)
B Cracks and surface damage
C Crack Filler and Repairing Materials
D Ressi SLS Primer – 1
E Ressi SLS 610
F Ressi EPO Primer LV
G Copper Strips
H Ressi EPO Anti-Static
I Ressi EPO Anti-Static (Marking)

View PDFView Application PDF